Home »
Testing & Quality Assurance
Testing & Quality Assurance
Quality has always been our priority.
Our products are certified as per IS: 9537 (Part III) Standards. In order to
assure best quality, all the tests are conducted in house as per the Bureau
Of Indian Standards (BIS), on a regular basis. The following tests are
conducted by our qualified engineers, in a well equipped and certified
Laboratory:
Marking Test
Marking parameters like manufacturers
name, nominal sizes, country of manufacture, strength & standard mark
are tested under this. Also a test for durability of marking is conducted
Dimension Test
The attributes tested in this are
Maximum and Minimum Outside and Inside Diameter, Length of conduit and
uniformity of wall thickness.
Construction Test
The requirements specified under this
test are that the inside and outside surface of conduit are reasonably
smooth and free from burrs, flash and similar defects; and the edges over
which the conductors or cables are likely to drawn does not damage the cable
or conductor.
Mechanical Property
The tests conducted for mechanical
properties are the bending test, compression test (during and after the
load), Impact test and Collapse test.
 |

Resistance to Heat
The diameter of impression should not
exceed 2mm. |

Resistance to Burning
Flame of the sample should have died out
in less than 30 seconds after removal of the burner. |

Electrical Characteristics Test
Electrical strength and Insulation
Resistance are tested under this step. |

Spring Bending Test
Though it is not a mandatory test
according to ISI, it is becoming a very popular test in the real
world. Every batch has to pass the spring bending test. The pipe
must not break by bending at 950 |
Bending Test |
Collapse Test |
Impact Test |
Compression Test |
|
 |